relative_humidity2vmr
- typhon.physics.relative_humidity2vmr(RH, p, T, e_eq=None)[source]
- Convert relative humidity into water vapor VMR. \[x = \frac{\mathrm{RH} \cdot e_s(T)}{p}\]- Note - By default, the relative humidity is calculated with respect to saturation over liquid water in accordance to the WMO standard for radiosonde observations. You can use - e_eq_mixed_mk()to calculate relative humidity with respect to saturation over the mixed-phase following the IFS model documentation.- Parameters:
- RH (float or ndarray) – Relative humidity. 
- p (float or ndarray) – Pressue [Pa]. 
- T (float or ndarray) – Temperature [K]. 
- e_eq (callable) – Function to calculate the equilibrium vapor pressure of water in Pa. The function must implement the signature - e_eq = f(T)where- Tis temperature in Kelvin. If- Nonethe function- e_eq_water_mk()is used.
 
- Returns:
- Volume mixing ratio [unitless]. 
- Return type:
- float or ndarray 
 - See also - vmr2relative_humidity()
- Complement function (returns RH for given VMR). 
- e_eq_water_mk()
- Used to calculate the equilibrium water vapor pressure. 
 - Examples - >>> relative_humidity2vmr(0.75, 101300, 300) 0.026185323887350429